Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Amperometry: Overview01:10

Amperometry: Overview

Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Serum concentrations of DDE, PCBs, and other persistent organic pollutants and mammographic breast density in Triana, Alabama, a highly exposed population.

Environmental research·2020
Same author

Meeting report from the joint IARC-NCI international cancer seminar series: a focus on colorectal cancer.

Annals of oncology : official journal of the European Society for Medical Oncology·2019
Same author

Impact of molecular structure on the physicochemical properties of starches isolated from different field pea (Pisum sativum L.) cultivars grown in Saskatchewan, Canada.

Food chemistry·2016
Same author

Professional Basketball Players: Athletic Profiles.

The Physician and sportsmedicine·2016
Same author

In vitro amylolysis of pulse and hylon VII starches explained in terms of their composition, morphology, granule architecture and interaction between hydrolysed starch chains.

Food chemistry·2015
Same author

Composition, structure, morphology and physicochemical properties of lablab bean, navy bean, rice bean, tepary bean and velvet bean starches.

Food chemistry·2014

Related Experiment Video

Updated: Jun 1, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
08:19

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing

Published on: June 1, 2012

Amperometric gas sensor response times.

P R Warburton1, M P Pagano, R Hoover

  • 1Draeger Safety Inc., 101 Technology Drive, P.O. Box 120, Pittsburgh, Pennsylvania 15230-0120.

Analytical Chemistry
|June 8, 2011
PubMed
Summary
This summary is machine-generated.

The response time of amperometric gas sensors depends on both gas diffusion and the working electrode's electrical properties. Increasing electrical resistance slows down sensor response, impacting overall performance.

More Related Videos

Fast and Accurate Exhaled Breath Ammonia Measurement
06:27

Fast and Accurate Exhaled Breath Ammonia Measurement

Published on: June 11, 2014

Related Experiment Videos

Last Updated: Jun 1, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
08:19

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing

Published on: June 1, 2012

Fast and Accurate Exhaled Breath Ammonia Measurement
06:27

Fast and Accurate Exhaled Breath Ammonia Measurement

Published on: June 11, 2014

Area of Science:

  • Electrochemistry
  • Sensor Technology
  • Chemical Engineering

Background:

  • Amperometric gas sensors are crucial for environmental monitoring and industrial safety.
  • Understanding factors affecting sensor response time is vital for accurate gas detection.
  • The interplay between diffusion and electrical properties in sensor performance requires detailed investigation.

Purpose of the Study:

  • To investigate the relative contributions of diffusion and electrical time constants to the response time of amperometric gas sensors.
  • To quantify the impact of electrical resistance on sensor response characteristics.
  • To develop a comprehensive model explaining sensor behavior based on electrochemical principles.

Main Methods:

  • Experimental measurement of an electrochemical carbon monoxide sensor's response to CO gas with varying series resistance.
  • Comparison of experimental data with theoretical predictions based on Fick's second law of diffusion.
  • Modeling sensor behavior using an equivalent electrical circuit to describe working electrode time constants.
  • Analysis of electrochemical impedance spectra to validate model parameters.

Main Results:

  • Sensor response time was found to increase with increasing electrical resistance in the working electrode circuit.
  • Experimental results were consistent with theoretical models incorporating both diffusion and electrical time constants.
  • The equivalent electrical circuit model accurately described the observed sensor behavior.
  • Electrochemical impedance spectroscopy data corroborated the model's predictions.

Conclusions:

  • The response time of amperometric gas sensors is significantly influenced by both the rate of gas diffusion and the electrical time constants of the working electrode.
  • Electrical properties, specifically the time constant, play a critical role in determining sensor dynamics.
  • This study provides a framework for optimizing amperometric gas sensor design and performance by considering both mass transport and electrical characteristics.