Related Experiment Video
Updated: Jun 1, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Cyclic voltammetric detection in capillary electrophoresis with application to metal ions
1Chemistry Department, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada.
Abstract:
Fast cyclic voltammetry (CV) was evaluated over sweep rates of 20-1000 V/s at Au disk electrodes (25 and 10 μm) for end-capillary detection in capillary electrophoresis with metal ions as test analytes; some studies were also done with 25-μm Pt disk electrodes. The waveform applied to the electrode consisted of a preconcentration period (55-330 ms) followed by cyclic voltammetry (2-100 ms). Maximum signal-to-noise was obtained with the integrated CV current as the analytical signal, and this was linearly proportional to sweep rate; maximum response was obtained at sweep rates of >100 V/s for 10-μm electrodes and >200 V/s for 25-μm electrodes; sweep rates of >400 V/s caused peak tailing due to trapping of the analyte at the electrode. With this CV detection approach, comigrating analytes could be identified and determined. Reproducibilities for six analytes over the range 1.0 × 10(-)(7)-1.0 × 10(-)(5) mol/L were 2%-5%, and calibration curves were linear, with response factors in the range of 2%-6%. Detection limits (2 × peak-to-peak baseline noise) were in the range of 5 × 10(-)(9)-4 × 10(-)(8) mol/L, which are 1-2 orders of magnitude better than results obtained previously with square-wave pulsed amperometric detection of metal ions.
More Related Videos
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Voltammetric Techniques: Cyclic Voltammetry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...