Related Experiment Video
Updated: Jun 1, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Dithizone immobilized silica gel on-line preconcentration of trace copper with detection by flame atomic absorption
Hong-Mei Yu1, Hua Song, Ming-Li Chen
1Research Center for Analytical Sciences, College of Sciences, Northeastern University, Shenyang 110819, China.
Abstract:
A novel adsorbent-silica gel bound dithizone (H(2)Dz-SG) was prepared and used as solid-phase extraction of copper from complex matrix. The H(2)Dz-SG is investigated by means of FT-IR spectra and the SEM images, demonstrating the bonding of dithizone. The H(2)Dz-SG quantitatively adsorb copper ions, and the retained copper is afterwards collected by elution of 10% (v/v) nitric acid. An on-line flow injection solid-phase extraction procedure was developed for trace copper separation and preconcentration with detection by flame atomic spectrometry. By loading 5.4 mL of sample solution, a liner range of 0.5-120 μg L(-1), an enrichment factor of 42.6, a detection limit of 0.2 μg L(-1) and a precision of 1.7% RSD at the 40 μg L(-1) level (n=11) were obtained, along with a sampling frequency of 47 h(-1). The dynamic sorption capacity of H(2)Dz-SG to Cu(2+) was 0.76 mg g(-1). The accuracy of the proposed procedure was evaluated by determination of copper in reference water sample. The potential applications of the procedure for extraction of trace copper were successfully accomplished in water samples (tap, rain, snow, sea and river). The spiking recoveries within 91-107% are achieved.
More Related Videos
13:04Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells
Published on: May 16, 2019
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Precipitation and Co-precipitation
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Gas Chromatography: Types of Detectors-II
Extraction: Advanced Methods
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...