Anatomic localization and autonomic modulation of atrioventricular junctional rhythm in failing human hearts
Related Experiment Video
Updated: Jun 1, 2026

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Vadim V Fedorov1, Christina M Ambrosi, Geran Kostecki
1Department of Biomedical Engineering, Washington University in St Louis, MO, USA.
Background:
The structure-function relationship in the atrioventricular junction (AVJ) of various animal species has been investigated in detail; however, less is known about the human AVJ. In this study, we performed high-resolution optical mapping of the human AVJ (n = 6) to define its pacemaker properties and response to autonomic stimulation.
Methods And Results:
Isolated, coronary-perfused AVJ preparations from failing human hearts (n = 6, 53 ± 6 years) were optically mapped using the near-infrared, voltage-sensitive dye, di-4-ANBDQBS, with isoproterenol (1 micromol/L) and acetylcholine (1 micromol/L). An algorithm detecting multiple components of optical action potentials was used to reconstruct multilayered intramural AVJ activation and to identify specialized slow and fast conduction pathways (SP and FP). The anatomic origin and propagation of pacemaker activity was verified by histology. Spontaneous AVJ rhythms of 29 ± 11 bpm (n = 6) originated in the nodal-His region (n = 3) and/or the proximal His bundle (n = 4). Isoproterenol accelerated the AVJ rhythm to 69 ± 12 bpm (n = 5); shifted the leading pacemaker to the transitional cell regions near the FP and SP (n = 4) and/or coronary sinus (n = 2); and triggered reentrant arrhythmias (n = 2). Acetylcholine (n = 4) decreased the AVJ rhythm to 18 ± 4 bpm; slowed FP/SP conduction leading to block between the AVJ and atrium; and shifted the pacemaker to either the transitional cell region or the nodal-His region (bifocal activation).
Conclusions:
We have demonstrated that the AVJ pacemaker in failing human hearts is located in the nodal-His region or His bundle regions and can be modified with autonomic stimulation. Moreover, we found that both the FP and SP are involved in anterograde and retrograde conduction.
More Related Videos
05:16Whole-Mount Immunofluorescence Staining, Confocal Imaging and 3D Reconstruction of the Sinoatrial and Atrioventricular Node in the Mouse
Published on: December 22, 2020
10:53Isolation of Human Atrial Myocytes for Simultaneous Measurements of Ca2+ Transients and Membrane Currents
Published on: July 3, 2013
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Heart Failure II: Pathophysiology