Related Experiment Video
Updated: Jun 1, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Comparison of monolithic and 1.8-μm RP-18 silica capillary columns using chromatographic data and mass spectrometric
Johan Rozenbrand1, Gerhardus J de Jong, Wouter P van Bennekom
1Biomolecular Analysis, Faculty of Science, Department of Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands. J.Rozenbrand@uu.nl.
Abstract:
A goal in proteomics is the analysis of proteins by LC-MS. The proteins are enzymatically digested and the resulting peptides are chromatographically separated and introduced into a tandem MS. The obtained MS data are used for a search in sequence databases, providing identification scores for the proteins. A method to improve that score is to increase the chromatographic separation and peak capacity. In this study, the chromatographic conditions were optimized for a relatively large gradient time by varying the flow rate and gradient composition. The influence of the monolithic column length (15 and 64 cm) and particle diameter (1.8 μm; 15-cm length) on the sample peak capacity, productivity and identification score was studied. For comparison of gradient systems, a scaling factor was introduced to normalize the properties/performance of columns for material, diameter and length. As model proteins/digests, a simple (myoglobin) and a larger (BSA) protein were used. The smallest peak width, highest identification scores (54 and 89% for BSA and myoglobin, respectively) and productivity (5.0 and 4.0, respectively) were obtained for the 15-cm particulate column. The study also demonstrates that a further increase in the chromatographic performance is beneficial for BSA but hardly increases the identification score for the relatively small myoglobin.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...