Applications of Doppler ultrasound during labor
Dan Mihu1, Doru Diculescu, Nicolae Costin
1Dominic Stanca Obstetrics and Gynecology Clinic, Cluj-Napoca, Romania. dan.mihu@yahoo.com
Abstract:
The information provided by Doppler ultrasound examination during labor permits the understanding of the mechanisms regarding the physiology and pathophysiology of feto-placental exchange and the fetal adaptive systems. There are certain technical difficulties related to intrapartum Doppler ultrasound examination. The investigated sites are the uterine arteries, umbilical arteries, fetal circulation. In diastole, when intrauterine pressure exceeds maternal diastolic pressure, the perfusion pressure of the uterine artery blood flow is no longer present. A progressive decrease in the diastolic component is seen along with an increase in intrauterine pressure from 10 to 60 mmHg. During premature birth or preeclampsia, there are particular changes in the uterine blood flow. A remarkable stability of the umbilical resistance index is found during labor, which shows the permanent presence of feto-placental exchange. Certain correlations can be established between fetal heart rate changes in labor and Doppler ultrasound aspects at the level of umbilical arteries. Doppler examination confirms the concept of reduced cerebral blood flow by the compression of the fetal skull as a cause of decelerations occurring during labor. The decision regarding the extraction of the fetus can only be made by correlating the results of Doppler ultrasound with the other paraclinical methods for the monitoring of the intrapartum fetal status.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...