Mass transfer kinetics, band broadening and column efficiency

Fabrice Gritti1, Georges Guiochon

  • 1Department of Chemistry, University of Tennessee, Knoxville, TN 37996, USA.

Related Concept Videos

Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Diffusion on Chromatography Columns01:07

Diffusion on Chromatography Columns

In column chromatography, when an analyte is introduced as a narrow band at the top of the column, the solutes begin to separate and broaden, developing a Gaussian profile. This broadening occurs due to various factors, such as longitudinal diffusion.
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Column Efficiency: Plate Theory01:10

Column Efficiency: Plate Theory

Band broadening in a chromatography column is measured by its efficiency. This is determined by the number of theoretical plates (N). Theoretical plate theory states that a separation column consists of a continuous series of imaginary plates where solute equilibration occurs between stationary and mobile phases.
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...