Related Experiment Video
Updated: Jun 1, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Direct separation and detection of biogenic amines by ion-pair liquid chromatography with chemiluminescent nitrogen
Jingshun Sun1, Hong-Xun Guo, David Semin
1Amgen, Inc., One Amgen Center Drive, Thousand Oaks, CA 91320, USA. sun@amgen.com
Abstract:
Analysis of biogenic amines is critical to pharmaceutical and food industry due to their biological importance. For many years, the determination of biogenic amines has relied on high performance liquid chromatography (HPLC) coupling with pre-, on-, or post-column derivatization procedures to enable UV or fluorescent detections. In this study, 14 biogenic amines were separated on a Phenomenex Luna Phenyl-Hexyl column by an ion-pair liquid chromatography method using perfluorocarboxylic acids as ion-pair reagents and detected by a chemiluminescent nitrogen detector (CLND). This direct separation and detection HPLC method eliminated the time consuming and cumbersome derivatization procedures. Compared with HPLC-UV (post-column derivatization with ninhydrin) and HPLC-charged aerosol detector (CAD) methods, this HPLC-CLND technique provided narrower peaks, better baselines, and improved separations and detections. Excellent linearity was acquired by CLND for each of the 14 biogenic amines ranging from less than 1 ng to about 1000 ng (on-column weights). The relative response factors determined by this LC-CLND method were proportional to the numbers of nitrogen atoms in each compound, which has been the characteristic of the equimolar determinations by CLND. In addition, a number of samples including beer, dairy beverage, herb tea, and vinegar were analyzed by the LC-CLND method with satisfactory precision and accuracy.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Mass Spectrometry of Amines
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...