Related Experiment Video
Updated: Jul 23, 2026

Determining Genome-wide Transcript Decay Rates in Proliferating and Quiescent Human Fibroblasts
Published on: January 2, 2018
Optimization of filtration for the reduction of lung dose from Rn decay products: Part II--Experimental
C A Curling1, S N Rudnick, D P Harrington
1Harvard School of Public Health, Department of Environmental Science and Physiology, Boston, MA 02115.
Abstract:
Research was performed to determine the validity of a model developed to theoretically predict the optimal characteristics of a recirculating filter system for minimizing the lung dose to a person breathing airborne Rn progeny. Four designs, each with different filter thicknesses, solidities, and fiber diameters, were tested to evaluate the accuracy of the model over a range of parameters. Increasing thicknesses were then tested for the most effective filter design to provide a more definitive comparison of experimental data and model predictions for this key parameter. The experimental data supported the conclusion that the most effective design was a thin filter of low solidity composed of coarse fibers. Although the maximum reduction in the dose-equivalent rate observed in these experiments was 50%, this was largely due to constraints on the experimental arrangements. With properly constructed filter units, much better removal efficiencies can undoubtedly be achieved.