Related Experiment Video
Updated: May 31, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Test-retest reliability of the oxygen uptake efficiency slope in surgical patients
B J Phypers1, D Robiony-Rogers, R M Pickering
1Southampton University Hospitals NHS Trust, Southampton, UK. phypers@europe.com
Abstract:
The oxygen uptake efficiency slope is a measure of cardiopulmonary fitness, that can be obtained from a sub-maximal cardiopulmonary exercise test. It has been evaluated in medical patients but its reliability in surgical populations remains uncertain. We conducted a test-retest study with the aim of establishing the reliability of the oxygen uptake efficiency slope in relation to that of the anaerobic threshold and peak oxygen uptake, in general surgical patients. Twenty-six patients over 60 years old completed two symptom-limited, incremental cycle ergometry tests within 7 days. The mean (SD) anaerobic threshold was 13.0 (3.0) mlO(2) .kg(-1) .min(-1) . There were no significant differences between mean test and retest values of anaerobic threshold (p = 0.50), peak oxygen uptake (p = 0.76) or oxygen uptake efficiency slope (p = 0.42). Reliability coefficients (95% CI) for the anaerobic threshold, oxygen uptake efficiency slope and peak oxygen uptake were 66.7% (45.3-87.9%), 89.0% (81.0-96.9%) and 91.7% (85.7-97.8%), respectively. The oxygen uptake efficiency slope was determined easily in all patients and found to have excellent reliability. Its clinical utility in determining pre-operative fitness warrants further evaluation.
More Related Videos
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...