Related Experiment Video
Updated: May 31, 2026

Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
[Measurement of refractive index with a PM-LPG based Sagnac loop sensor]
Juan Kang1, Xin-Yong Dong, Chun-Liu Zhao
1Institute of Optoelectronic Technology, China Jiliang University, Hangzhou 310018, China. kangjuan@cjlu.edu.cn
Abstract:
By inscribing a long-period fiber grating (LPG) on a polarization-maintaining fiber (PMF), a fiber Sagnac loop sensor for simultaneous measurement of refractive index and temperature has been proposed and demonstrated. The LPG was fabricated on the PMF by using a CO2 laser, and then inserted into a fiber loop formed by using a normal single-mode fiber coupler. One of the transmission minimum of the Sagnac loop sensor was measured, whose wavelength varied with temperature and the intensity changed with refractive index. Temperature sensitivity of -0.654 nm x degrees C(-1) and refractive sensitivity of 49.9 dB x RIU(-1) have been achieved. The sensor system shows advantages of small size and low cost, and owns a good application prospect.

