Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
Published on: August 22, 2019
[Selection of interpolation methods used to mitigate spectral misregistration of imaging spectrometers]
Xu Chen1, Yang Xiang, Yu-Tao Feng
1State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China. chxu2009@126.com
Abstract:
Spectral curvature destroys the co-registration of the spectra measured by dispersion imaging spectrometer. Using interpolation to re-sample the measured spectra at the non-offset mid-wavelengths can mitigate the spectral misregistration. It is very important to select an optimum interpolation method. The performances of six common interpolation methods are evaluated by comparing the residual errors in the corrected spectral radiance. The results indicate that, four-point cubic Lagrange interpolation and cubic spline interpolation are better than other four interpolation methods (linear Interpolation, three points quadratic polynomial interpolation, five points four-order Lagrange interpolation and cubic Hermite interpolation). For spectral offset of 10% deltalambda (deltalambda = 5 nm), the normalized errors in measured spectral radiance is PV = 0.06, that is reduced to PV < 0.022 after interpolation with cubic Lagrange interpolation or cubic spline interpolation, but for other four methods they are PV > 0.035. Furthermore, for lower spectral resolution (deltalambda > 5 nm), cubic Lagrange interpolation is a little better than cubic spline interpolation; while for higher spectral resolution (deltalambda < 5 nm), cubic spline interpolation is a little better.
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
IR Spectrometers
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...