Related Experiment Video
Updated: May 31, 2026

Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Surface ozone comparison conducted in two rural areas in central-southern Spain
Alberto Notario1, Yolanda Díaz-de-Mera, Alfonso Aranda
1Departamento de Química Física, Instituto de Tecnologías Química y Medioambiental (ITQUIMA), Universidad de Castilla La Mancha, Ciudad Real, Spain.
Purpose:
The purpose of this work is to contribute to the understanding of the photochemical air pollution analysing the levels and temporal variations of surface ozone in two rural areas situated in central-southern Spain.
Method:
The study is based on ozone hourly data recorded during the overall period between January 2008 and November 2009. The seasonal and daily ozone cycles as well as the number of exceedances of the threshold established in the European Ozone Directive have been calculated and analysed.
Results:
This study presents the first ozone data registered at these two rural sites in the Iberian Peninsula plateau. Ozone shows a clear seasonal variation with the lowest values in January and November. High ozone concentrations are interrelated with high radiation intensities, temperature and wind directions. The information threshold defined in the European Ozone Directives was exceeded six times, while the limit for protection of human health was exceeded more than 40 times. The limits to protect the vegetation were also exceeded.
Conclusions:
Porzuna (near Cabañeros National Park) presents higher ozone levels than Argamasilla during the night-time and during the daytime of the summer months. Ozone levels are lower in Argamasilla probably due to fresh emissions from the close industrial area of Puertollano. The ozone exceedances of the limits defined in the Ozone Directive point out an ozone problem in this rural region.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Flame Photometry: Lab
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Oxidative Cleavage of Alkenes: Ozonolysis
Ozone is a symmetrical bent molecule stabilized by a resonance structure.

