Related Experiment Video
Updated: May 31, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Daily interruption of sedation in patients receiving mechanical ventilation
Leonie Weisbrodt1, Sharon McKinley, Andrea P Marshall
1Nepean Hospital, Penrith, New South Wales, Australia. Leonie.Weisbrodt@sydney.edu.au
Background:
Daily interruption of continuous infusion of sedatives has improved outcomes in patients receiving mechanical ventilation in open-label studies.
Objectives:
To assess the feasibility of a protocol for a double-blind, randomized, controlled trial study on the impact of routine daily interruption of sedation in patients receiving mechanical ventilation.
Methods:
A total of 50 patients receiving mechanical ventilation were randomized to daily interruption of fentanyl and/or midazolam infusions for up to 6 hours or to usual management of sedation. Blinding was achieved by using replacement infusions (saline or active drug in saline).
Results:
The recruitment target of 80 patients was not met in an extended time frame. Propofol was used outside the protocol in 27% of patients in the intervention group and 17% of patients in the control group (P = .10). A total of 15% of the intervention group and 12% of the control group never had replacement infusions started (P = .77), and replacement infusions were started on only approximately one-third of eligible days in patients who received replacement infusions. The mean doses of fentanyl and midazolam were similar. The blinding strategy was safe and effective: no patients had unplanned extubations, and the most frequent reason for ending replacement infusions was completion of the maximum 6-hour period.
Conclusions:
The double-blinded design for assessment of sedation interruption in patients receiving mechanical ventilation was safe and effective. Slow recruitment of patients and frequent noncompliance with the protocol suggest that modifications to the protocol are needed.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Stages of General Anesthesia