Optimization of the radiological protection of patients undergoing digital radiography
1Shandong Medical Imaging Research Institute, Jingwu Road No. 324, Jinan, China. menglongzhang@163.com
Abstract:
Because of a much higher dynamic range of flat panel detectors, patient dose can vary without change of image quality being perceived by radiologists. This condition makes optimization (OT) of radiation protection undergoing digital radiography (DR) more complex, while a chance to reduced patient dose also exists. In this study, we evaluated the difference of patient radiation and image rejection before and after OT to identify if it is necessary to carry out an OT procedure in a routine task with DR. The study consisted of a measurement of the dose area product (DAP) and entrance surface dose (ESD) received by a reference group of patients for eight common radiographic procedures using the DR system before and after OT. Meanwhile image rejection data during two 2-month periods were collected and sorted according to reason. For every radiographic procedure, t tests showed significant difference in average ESD and DAP before and after OT (p < 0.005). The ESDs from most examinations before OT were three times higher than that after OT. For DAPs, the difference is more significant. Image rejection rate after OT is significantly lower than that before OT (χ (2) = 36.5, p < 0.005). The substantial reductions of dose after OT resulted from appropriate mAs and exposure field. For DR patient dose, less than recommended diagnostic reference level can meet quality criteria and clinic diagnosis.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...