Related Experiment Video
Updated: May 31, 2026

Postural Organization of Gait Initiation for Biomechanical Analysis Using Force Platform Recordings
Published on: July 26, 2022
Calculation of plantar pressure time integral, an alternative approach
Tom Melai1, T Herman IJzerman, Nicolaas C Schaper
1Department of Health Innovation & Technology, Institute of Allied Health Professions, Fontys University of Applied Sciences, PO Box 347, NL-5600 AH, Eindhoven, The Netherlands. T.Melai@Fontys.nl
Abstract:
In plantar pressure measurement, both peak pressure and pressure time integral are used as variables to assess plantar loading. However, pressure time integral shows a high concordance with peak pressure. Many researchers and clinicians use Novel software (Novel GmbH Inc., Munich, Germany) that calculates this variable as the summation of the products of peak pressure and duration per time sample, which is not a genuine integral of pressure over time. Therefore, an alternative calculation method was introduced. The aim of this study was to explore the relevance of this alternative method, in different populations. Plantar pressure variables were measured in 76 people with diabetic polyneuropathy, 33 diabetic controls without polyneuropathy and 19 healthy subjects. Peak pressure and pressure time integral were obtained using Novel software. The quotient of the genuine force time integral over contact area was obtained as the alternative pressure time integral calculation. This new alternative method correlated less with peak pressure than the pressure time integral as calculated by Novel. The two methods differed significantly and these differences varied between the foot sole areas and between groups. The largest differences were found under the metatarsal heads in the group with diabetic polyneuropathy. From a theoretical perspective, the alternative approach provides a more valid calculation of the pressure time integral. In addition, this study showed that the alternative calculation is of added value, along peak pressure calculation, to interpret adapted plantar pressures patterns in particular in patients at risk for foot ulceration.
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Substitution Rule Applied to Indefinite Integrals
Application of Integration: Problem Solving
Integration by Parts: Indefinite Integrals
Applications of Integration to Find Hydrostatic Pressure
Integration by Parts: Definite Integrals