Precision Measurements and Parametric Models of Vertebral Endplates
Published on: September 17, 2019
Finite element lumbar spine facet contact parameter predictions are affected by the cartilage thickness distribution
Daniel J Woldtvedt1, Wesley Womack, Benjamin C Gadomski
1Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, 1374 Campus Delivery, Fort Collins, CO 80523-1374, USA.
Abstract:
Current finite element modeling techniques utilize geometrically inaccurate cartilage distribution representations in the lumbar spine. We hypothesize that this shortcoming severely limits the predictive fidelity of these simulations. Specifically, it is unclear how these anatomically inaccurate cartilage representations alter range of motion and facet contact predictions. In the current study, cadaveric vertebrae were serially sectioned, and images were taken of each slice in order to identify the osteochondral interface and the articulating surface. A series of custom-written algorithms were utilized in order to quantify each facet joint's three-dimensional cartilage distribution using a previously developed methodology. These vertebrae-dependent thickness cartilage distributions were implemented on an L1 through L5 lumbar spine finite element model. Moments were applied in three principal planes of motion, and range of motion and facet contact predictions from the variable thickness and constant thickness distribution models were determined. Initial facet gap thickness dimensions were also parameterized. The data indicate that the mean and maximum cartilage thickness increased inferiorly from L1 to L5, with an overall mean thickness value of 0.57 mm. Cartilage distribution and initial facet joint gap thickness had little influence on the lumbar range of motion in any direction, whereas the mean contact pressure, total contact force, and total contact area predictions were altered considerably. The data indicate that range of motion predictions alone are insufficient to establish model validation intended to predict mechanical contact parameters. These data also emphasize the need for the careful consideration of the initial facet joint gap thickness with respect to the spinal condition being studied.
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary or...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Members Made of Elastoplastic Material
As the bending moment...
General Structure of a Vertebra
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form the...