Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent

Jerry S Cheung1, Enfeng Wang, XiaoAn Zhang

  • 1Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA.

NMR in Biomedicine
|July 15, 2011
PubMed

Insights

Accurate transverse relaxation time (T2) MRI measurements are crucial for disease diagnosis. A new fast radio-frequency enforced steady state (FRESS) spin echo (SE) sequence minimizes errors caused by short scan times, improving T2 accuracy.

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Biomedical Engineering
  • Medical Physics

Background:

  • Transverse relaxation time (T2) is a fundamental MRI parameter vital for diagnosing various conditions like multiple sclerosis, stroke, and tumors.
  • Conventional MRI techniques often employ short repetition times (TR) to reduce scan duration, potentially introducing significant errors in T2 quantification.
  • The dependence of steady-state magnetization on echo time (TE) in standard sequences can lead to T2 underestimation if not correctly addressed.

Purpose of the Study:

  • To develop a novel MRI sequence for accurate and rapid T2 quantification.
  • To mitigate T2 measurement errors arising from short TR and TE-dependent steady-state magnetization.
  • To introduce a fast radio-frequency enforced steady state (FRESS) spin echo (SE) MRI technique.

Main Methods:

  • A fast radio-frequency enforced steady state (FRESS) spin echo (SE) MRI sequence was designed to ensure a TE-independent steady state by saturating magnetization post-echo.
  • The FRESS-SE sequence was evaluated using numerical simulations to assess its theoretical performance.
  • The sequence was implemented with an echo-planar imaging (EPI) readout for rapid data acquisition.
  • Validation was performed using both phantom studies and in vivo experiments.

Main Results:

  • Numerical simulations confirmed the TE-independent steady-state property of the FRESS-SE sequence.
  • The FRESS-SE MRI technique demonstrated the capability for fast and accurate T2 mapping.
  • Phantom and in vivo experiments validated the practical applicability and accuracy of the proposed method.

Conclusions:

  • The developed FRESS-SE T2 MRI technique offers a solution for fast and accurate T2 imaging.
  • This method effectively overcomes the limitations of conventional sequences regarding TE dependence and scan time.
  • The FRESS-SE technique is suitable for routine in vivo applications, enhancing diagnostic capabilities.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Atomic Nuclei: Types of Nuclear Relaxation01:28

Atomic Nuclei: Types of Nuclear Relaxation

Nuclear relaxation restores the equilibrium population imbalance and can occur via spin–lattice or spin–spin mechanisms, which are first-order exponential decay processes.
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers energy to a nearby...
Two-Dimensional (2D) NMR: Overview01:12

Two-Dimensional (2D) NMR: Overview

The 1D NMR spectrum of large and complex molecules like natural products has complicated splitting patterns and overlapping signals, which can be easily interpreted using 2-dimensional (2D) NMR. Unlike 1D NMR, 2D NMR has two frequency axes that provide the coupling information between the nucleus A and nucleus B in a molecule. The process from which 2D spectra are obtained has four steps.
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...