Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent
Jerry S Cheung1, Enfeng Wang, XiaoAn Zhang
1Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA.
Abstract:
Transverse relaxation time (T(2)) is a basic but very informative MRI parameter, widely used in imaging to examine a host of diseases, including multiple sclerosis, stroke, and tumor. However, short repetition time (TR) is often used to minimize scan time, which may introduce non-negligible errors in T(2) measurement. Specifically, due to the use of refocusing pulse, the steady state magnetization depends not only on TR but also on the TE. Hence, if the TE dependence is not properly accounted for, it may be mistaken as T(2)-induced signal attenuation, leading to non-negligible T(2) underestimation. Our study proposed a fast radio-frequency enforced steady state (FRESS) spin echo (SE) MRI sequence, which saturates the magnetization after the echo and ensures a TE-independent steady state. The proposed FRESS-SE MRI was evaluated with numerical simulation, implemented with echo planar imaging readout, and validated by both phantom and in vivo experiments. In summary, FRESS-SE T(2) MRI technique was developed for fast and accurate T(2) imaging, suitable for in vivo applications.
Insights
Accurate transverse relaxation time (T2) MRI measurements are crucial for disease diagnosis. A new fast radio-frequency enforced steady state (FRESS) spin echo (SE) sequence minimizes errors caused by short scan times, improving T2 accuracy.
Area of Science:
- Magnetic Resonance Imaging (MRI)
- Biomedical Engineering
- Medical Physics
Background:
- Transverse relaxation time (T2) is a fundamental MRI parameter vital for diagnosing various conditions like multiple sclerosis, stroke, and tumors.
- Conventional MRI techniques often employ short repetition times (TR) to reduce scan duration, potentially introducing significant errors in T2 quantification.
- The dependence of steady-state magnetization on echo time (TE) in standard sequences can lead to T2 underestimation if not correctly addressed.
Purpose of the Study:
- To develop a novel MRI sequence for accurate and rapid T2 quantification.
- To mitigate T2 measurement errors arising from short TR and TE-dependent steady-state magnetization.
- To introduce a fast radio-frequency enforced steady state (FRESS) spin echo (SE) MRI technique.
Main Methods:
- A fast radio-frequency enforced steady state (FRESS) spin echo (SE) MRI sequence was designed to ensure a TE-independent steady state by saturating magnetization post-echo.
- The FRESS-SE sequence was evaluated using numerical simulations to assess its theoretical performance.
- The sequence was implemented with an echo-planar imaging (EPI) readout for rapid data acquisition.
- Validation was performed using both phantom studies and in vivo experiments.
Main Results:
- Numerical simulations confirmed the TE-independent steady-state property of the FRESS-SE sequence.
- The FRESS-SE MRI technique demonstrated the capability for fast and accurate T2 mapping.
- Phantom and in vivo experiments validated the practical applicability and accuracy of the proposed method.
Conclusions:
- The developed FRESS-SE T2 MRI technique offers a solution for fast and accurate T2 imaging.
- This method effectively overcomes the limitations of conventional sequences regarding TE dependence and scan time.
- The FRESS-SE technique is suitable for routine in vivo applications, enhancing diagnostic capabilities.
Related Concept Videos
Magnetic Resonance Imaging
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers energy to a nearby...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
NMR Spectrometers: Resolution and Error Correction