Background:
The maximum power output (MPO) of a hearing aid was typically discussed in the context of avoiding loudness discomfort. However, an MPO that is too low, as in the cases to avoid discomfort for people with a severe loudness tolerance problem and hearing losses that exceed the fitting range of the hearing aids, could negatively affect sound quality and speech intelligibility in noise.
Purpose:
The current study was designed to demonstrate the degradation in speech intelligibility in noise on the HINT (Hearing in Noise Test) when the MPO of the wearers' hearing aids was lowered by 10 dB from the default. The interactions with noise reduction (NR) algorithms (classic [NR-classic] and Speech Enhancer [NR-SE]) were also examined.
Research Design:
A single-blinded, factorial repeated-measures design was used to study the effect of noise input level (68 dBC, 75 dBC), MPO setting (default and default-10), and NR algorithm (off, classic, SE) on HINT performance.
Study Sample:
Eleven adults with a severe sensorineural hearing loss participated.
Intervention:
Participants were fit with the Widex m4-19 behind-the-ear hearing aids binaurally in the default frequency response and MPO settings. The hearing aids were adjusted to six MPO (default, default-10) by NR (off, classic, SE conditions). Testing was completed within one 2 hr session.
Data Collection And Analysis:
The RTS (reception threshold for speech) for 50% correct on the HINT was measured in each of the six hearing aid conditions at two input levels (68 and 75 dBC) with speech and noise stimuli presented from the front. Repeated-measures ANOVAs were conducted using SPSS software to examine significant differences.
Results:
A repeated-measures ANOVA showed that noise level was not significant while NR algorithm and MPO were significant. The interaction between noise level and NR algorithm was also significant. Post hoc analysis with Bonferroni adjustment for the effect of NR algorithm showed that performance with NR-off was significantly poorer than performance with NR-classic and NR-SE (p < 0.05). However, NR-classic and NR-SE were not significantly different from each other (p > 0.05).
Conclusions:
An MPO that was 10 dB lower than the default could negatively affect the signal-to-noise ratio (SNR) of the listening environment. However, NR could compensate for the degradation in SNR.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Maximum Power Transfer
By substituting the entire circuit with...
The Maximum Power Transfer Theorem
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Average Power
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.