Related Experiment Video
Updated: May 31, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Two-dimensional speckle tracking imaging detects impaired myocardial performance in children with septic shock, not
Sonali Basu1, Lowell H Frank, Kimberly E Fenton
1Department of Pediatric Critical Care Medicine, Children's National Medical Center, George Washington University School of Medicine, Washington, DC, USA. sbasu@cnmc.org
Objective:
Sepsis is common in children and often results in cardiac dysfunction. Assessment of patients with sepsis-associated myocardial depression using ejection fraction and fractional shortening with conventional echocardiography is load dependent and often reveals cardiac dysfunction only after clinical deterioration has occurred. Speckle tracking imaging is a novel technology that can assess deformation and strain by tracking displacement of acoustic markers in the myocardium. We hypothesize that speckle tracking imaging will detect cardiac impairments during sepsis that are not appreciated by conventional echocardiography.
Design:
Retrospective, observational study.
Setting:
A large, tertiary-care pediatric intensive care unit.
Patients:
Fifteen pediatric patients with septic shock, and 30 age- and gender-matched healthy controls.
Interventions:
Transthoracic echocardiograms from subjects with septic shock (by American College of Chest Physicians/Society of Critical Care Medicine consensus criteria) and controls were evaluated. Speckle tracking imaging was used to obtain tissue displacement, velocity, strain, and strain rate in radial, longitudinal, and circumferential planes. Ejection fraction and fractional shortening were determined by conventional methods. Comparisons between groups were made using a paired t test.
Measurements And Main Results:
Compared to control subjects, children with septic shock demonstrated impaired myocardial performance as quantified by speckle tracking imaging. Significant differences were seen in circumferential and longitudinal strain (p < .001), strain rate (p < .05), radial displacement (p < .001), and rotational velocity and displacement (p < .01). There was no significant difference in ejection fraction and fractional shortening between septic patients and controls.
Conclusions:
Speckle tracking imaging detected a number of significantly impaired measures of ventricular performance in children with sepsis, not appreciated by conventional echocardiography. This technology may improve our understanding and identification of myocardial depression in the critically ill septic child.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
07:13Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns
Published on: December 22, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Acute Coronary Syndrome III: Diagnostic Studies