Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry
Shibal Bhartiya1, Shveta Jindal Bali, Reetika Sharma
1Glaucoma Facility, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India. shibalbhartiya@gmail.com
Abstract:
To compare the tonometric recordings of the Tono-Pen AVIA (TPA) with intraocular pressure (IOP) recordings made with Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT). This prospective, observational, comparative case series consisted of 180 eyes of 180 subjects (50 patients with glaucoma and 130 healthy controls). NCT was performed first, followed by GAT and TPA measurement after a 5-min break. The mean age of the patients enrolled in the study was 43.99±16.67 years. The limits of agreement (confidence interval 95%) as calculated from the Bland-Altman plots for TPA-GAT and TPA-NCT were +8.7 to -7.7 and +8.6 to -9.6 mmHg in glaucoma patients. In healthy subjects these values were +4.8 to -5.1 and +6.2 to -5.2 mmHg, respectively. TPA tends to overestimate IOP compared to GAT at central corneal thickness (CCT) greater than 520 μm and underestimate IOP at CCT less than 510 μm. TPA overestimates IOP in comparison to NCT in subjects with CCT greater than 456 μm. Due to wide limits of agreement, TPA cannot be used interchangeably with GAT and NCT in the serial monitoring of glaucoma patients. Central corneal thickness has a significant influence on the IOP readings measured by Tono-Pen AVIA.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...