Related Experiment Video
Updated: May 30, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
DynaCT in pre-treatment evaluation of aortic aneurysm before EVAR
Objective:
DynaCT(®) is a method for obtaining computed tomography (CT)-like images using a C-arm system. Our aim was to compare the accuracy of these images to multidetector CT (MDCT) images prior to endovascular aortic repair (EVAR).
Methods:
A non-consecutive group of 20 elective patients were prospectively exposed to MDCT and one additional DynaCT before EVAR. Six arterial measurements and nine anatomical areas were chosen to: (1) visualise the peri-aortic soft tissue and assess the possibility to diagnose a potential haemorrhage from a ruptured aneurysm and (2) make the pre-treatment measurements before insertion of stent graft. Differences between modalities and readers were statistically compared using a linear mixed model.
Results:
For maximum aortic diameter, a significant difference of 1.3 mm was found between techniques (p = 0.043). Visibility scores were significantly better for all areas in MDCT data. Pre-treatment evaluation with DynaCT before EVAR was possible for all areas; evaluation of the iliac arteries were suboptimal due to a limited imaging volume size. Significant inter-reader differences were found for all anatomical areas.
Conclusion:
The result indicates that DynaCT gives sufficient information to determine the correct treatment and for selecting the proper stent graft before EVAR. A limited volume size reduces the evaluation of the iliac arteries.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests