Image quality of low-energy pulmonary CT angiography: comparison with standard CT
Naama R Bogot1, Alexander Fingerle, Dorith Shaham
1Department of Radiology, Hadassah-Hebrew University Medical Center, PO Box 12000, Jerusalem 91120, Israel.
Objective:
The purpose of this article is to prospectively compare visualization of central and peripheral pulmonary arteries on simultaneously acquired low-energy and standard pulmonary CT angiography.
Subjects And Methods:
Thirty-three consecutive patients (20 women and 13 men; mean age, 55.6 years; range, 21-92 years) with suspected pulmonary embolism (PE) were scanned (140 kVp; 250-300 mA) on a single-source dual-layer dual-energy MDCT scanner. Attenuation and image noise were measured at the main and segmental pulmonary arteries. Signal-to-noise ratios were calculated. Two blinded experienced radiologists assessed segmental and subsegmental artery visibility in consensus, using slab maximum-intensity-projection (MIP) reconstructions. Nonparametric sign test and kappa statistic were used for statistical analysis.
Results:
PE was detected in three patients (9.1%); two segmental vessel and subsegmental emboli were seen in the low-energy images only. Higher attenuation was noted in low-energy versus standard images for all arteries evaluated, with a mean (± SD) increase of 66.6 ± 4.4 HU (p < 0.0001). Low-energy images improved visualization of segmental and subsegmental arteries from 97.0% to 99.2% and from 88.0% to 93.9%, respectively. A larger number of subsegmental vessels was seen on low-energy MIP reconstructions in 69.7% (95% CI, 36.5-71.89%) of studies compared with 9.1% on the standard images. Visualization of subsegmental vessels was superior in 55.5% of cases using low-energy imaging. The mean image noise increased by 9.7 ± 0.6 HU (p < 0.0001). The mean signal-to-noise ratio showed no significant difference in the low-energy (8.2) versus standard (8.1) CT images (p = 0.7759).
Conclusion:
Improved visualization of central and peripheral arteries can be obtained with low-energy pulmonary CT angiography, without a substantial decrease in image quality.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT