Detection of vertical root fractures by using cone-beam computed tomography: a clinical study
Mitchell Edlund1, Madhu K Nair, Umadevi P Nair
1Department of Endodontics, College of Dentistry, University of Florida, Gainesville, Florida 32610-0436, USA. unair@dental.ufl.edu
Introduction:
Vertical root fractures of teeth (VRFs) often pose a diagnostic dilemma because of the difficulty in detection of these in intraoral radiographs except in certain cases with very distinct clinical findings. This often leads to unwarranted extraction of the tooth. Cone-beam computed tomography (CBCT) produces three-dimensional images and allows precise visualization and evaluation of VRFs or cracks in extracted teeth, as reported previously. This clinical pilot study was designed to determine the diagnostic accuracy of noninvasive CBCT for detection of suspected VRFs in endodontically treated teeth by using exploratory surgery to confirm the presence or absence of a fracture.
Methods:
Thirty-two teeth in 29 patients with clinical signs and symptoms suggestive of VRF were included in the study after informed consent was obtained. They underwent a limited area CBCT evaluation. All CBCT studies were blinded, and 2 board-certified oral and maxillofacial radiologists assessed the presence or absence of VRF through sequential evaluation of the three-dimensional volume. Subjects underwent surgical exploration as part of treatment, which helped establish the presence or absence of VRF.
Results:
Pearson correlation coefficient by using surgical finding to confirm presence/absence of fracture was 0.602, positive predictive value was 91%, and negative predictive value was 67%. The sensitivity was 88%, and specificity was 75%.
Conclusions:
This study revealed the superior diagnostic accuracy of CBCT for detection of VRF.
More Related Videos
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...