Two-beam pulsed Doppler cardiac output measurement: reproducibility and agreement with thermodilution
1Department of Anesthesiology, Veterans Administration Medical Center, Long Beach, CA 90822.
Abstract:
Two observers used two-beam pulsed Doppler ultrasound, equipped with a suprasternal probe, to measure cardiac output (QtDopp) in 38 ICU patients who had pulmonary artery catheters and in 20 adult volunteers. The two-beam pulsed Doppler method enables one device to measure simultaneously both aortic blood velocity and aortic diameter. Each observer was blind to the other's measurement and to the thermodilution cardiac output measurement (Qttd). Linear regression of the mean of both observer's QtDopp on Qttd showed QtDopp = 0.90.Qttd + 0.01 (see = 1.54 L/min, r = .90). Bias (+/- SD), defined as mean (QtDopp - Qttd) difference, was -0.69 +/- 1.55 L/min. Interobserver agreement was more variable in patients than volunteers; mean (observer 1 - observer 2) difference was 0.14 +/- 1.30 L/min in ICU patients and -0.09 +/- 0.92 L/min in volunteers. Two-beam pulsed Doppler ultrasound is a simpler method of measuring QtDopp than previous pulsed Doppler methods which measure separately the aortic diameter by echocardiography. Although its agreement with Qttd is close to other Doppler methods and has acceptable interobserver reproducibility, its accuracy remains operator-dependent.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...