Related Experiment Video
Updated: May 30, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Radiation exposure in children during the current era of pediatric cardiac intervention
Maiy Hamdy El Sayed1, Alaa Mahmoud Roushdy, Hala El Farghaly
1Cardiology Department, Ain Shams University Hospital, 21 Gamal El Deen Dweedar Street, Nasr City, Cairo, 11371, Egypt.
Insights
Pediatric cardiac catheterizations involve significant radiation exposure. Fluoroscopy time directly correlates with dose-area product and cumulative dose, highlighting the need for radiation management strategies in these procedures.
Area of Science:
- Medical Imaging
- Pediatric Cardiology
- Radiation Oncology
Background:
- Cardiac catheterizations are high-radiation X-ray procedures, particularly concerning for pediatric patients.
- Congenital heart diseases in children often require these interventions, necessitating careful radiation dose evaluation.
Purpose of the Study:
- To identify factors influencing X-ray exposure variability in pediatric cardiac catheterizations.
- To analyze the relationship between procedure type and radiation dose metrics.
Main Methods:
- A study involving 107 children undergoing diagnostic or interventional cardiac catheterization.
- Data collection on patient and procedural characteristics using a custom sheet.
- Correlation analyses to determine factors affecting X-ray exposure.
Main Results:
- Interventional procedures had significantly longer fluoroscopy times (FT) and higher dose-area product (DAP) than diagnostic ones.
- Fluoroscopy time showed a significant positive correlation with both DAP (r=0.718) and cumulative dose (CD) (r=0.701).
- Highest DAP was observed during specific angulations (LAO cranial 30°).
Conclusions:
- Complexity of interventional cardiac catheterizations in children leads to increased radiation exposure.
- Understanding factors influencing radiation variability is crucial for optimizing patient safety.
- Continued performance of therapeutic catheterizations underscores the need for effective radiation dose reduction strategies.
Abstract:
Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The fluoroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose-area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm(2) vs. 13.239 ± 15.4 Gy/cm(2); P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm(2)/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for therapeutic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Pharmacokinetics in Pediatric Patients: Drug Excretion