Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Immediate and short term effects of percutaneous atrial septal defect device closure on cardiac electrical remodeling
Alaa Mahmoud Roushdy1, Hebatalla Attia1, Heba Nossir1
1Cardiology Department, Ain Shams University Hospital, Cairo, Egypt.
Insights
Device closure for atrial septal defect (ASD) rapidly improves cardiac electrical remodeling in children. Significant positive changes in P wave and QT intervals are observed within 24 hours and sustained long-term.
Area of Science:
- Cardiology
- Pediatric Electrophysiology
Background:
- Atrial septal defect (ASD) is associated with electrical cardiac remodeling.
- Device closure is a known treatment for ASD, but its immediate impact on electrical remodeling is not fully understood.
Purpose of the Study:
- To investigate the immediate and short-term effects of percutaneous ASD device closure on cardiac electrical remodeling in pediatric patients.
Main Methods:
- Electrocardiograms (ECG) were performed on 30 children before, and 24 hours, 1 month, and 6 months after ASD device closure.
- Key ECG parameters including P wave and QT durations and dispersions were measured and analyzed.
Main Results:
- Significant reductions in P wave and QT dispersions were observed as early as 24 hours post-procedure.
- These improvements in electrical parameters continued at 1 month and were maintained at 6 months follow-up.
Conclusions:
- Percutaneous ASD device closure rapidly reverses electrical remodeling in both atrial and ventricular myocardium.
- The beneficial effects on cardiac electrical activity are evident within 24 hours and persist long-term.
Background:
The beneficial effects of atrial septal defect (ASD) device closure on electrical cardiac remodeling are well established. The timing at which these effects starts to take place has yet to be determined.
Objectives:
To determine the immediate and short term effects of ASD device closure on cardiac electric remodeling in children.
Methods:
30 pediatric patients were subjected to 12 lead Electrocardiogram immediately before ASD device closure, 24 h post procedure, 1 and 6 months after. The maximum and minimum P wave and QT durations in any of the 12 leads were recorded and P wave and QT dispersions were calculated and compared using paired T test.
Results:
The immediate 24 h follow up electrocardiogram showed significant decrease in P maximum (140.2 ± 6 versus 130.67 ± 5.4 ms), P dispersion (49.73 ± 9.01 versus 41.43 ± 7.65 ms), PR interval (188.7 ± 6.06 ms versus 182.73 ± 5.8 ms), QRS duration (134.4 ± 4.97 ms versus 127.87 ± 4.44), QT maximum (619.07 ± 15.73 ms versus 613.43 ± 11.87), and QT dispersion (67.6 ± 5.31 versus 62.6 ± 4.68 ms) (P = 0.001). After 1 month all the parameters measured showed further significant decrease with P dispersion reaching 32.13 ± 6 (P = 0.001) and QT dispersion reaching 55.0 ± 4.76 (P = 0.001). These effects were maintained 6 months post device closure.
Conclusion:
Percutaneous ASD device closure can reverse electrical changes in atrial and ventricular myocardium as early as the first 24 h post device closure.
More Related Videos
23:33The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Nucleosome Remodeling
Nucleosome remodeling complex
Eukaryotic cells have specialized enzymes called ATP-dependent nucleosome remodeling enzymes. These enzymes...
Bone Remodeling
Biological Effects of Radiation
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Long-term Depression
Angle Closure Glaucoma: Treatment