Related Experiment Video
Updated: May 30, 2026

Zebra II as A Novel System to Record Electrophysiological Signals in Zebrafish
Published on: August 16, 2024
Digital Holter measurement of QT prolongation in ziprasidone overdose
Ingrid Berling1, Geoffrey K Isbister, Leonie Calver
1Department of Clinical Toxicology and Pharmacology, Calvary Mater Newcastle, Newcastle, Australia. ingrid.berling@gmail.com
Objective:
QT prolongation is an important complication in drug overdose, particularly with some antidepressants and antipsychotics. There are problems with the accurate measurement of the QT interval and determining for what QT interval patients should be monitored, because of the risk of torsades des pointes (TdP). We report a case of ziprasidone overdose with QT prolongation, demonstrating different methods of measuring the QT interval.
Case Report:
A 47-year-old female presented after taking 1.2 g of ziprasidone and 250 mg of diazepam. She was taking propranolol and venlafaxine therapeutically. She developed bradycardia and QT prolongation (540 msec). She was transferred to a telemetry bed and observed for 48 h until her QT interval returned to normal (460 msec). QT intervals were extracted from (1) 12-lead digital Holter recordings (gold standard); (2) automated measurements on standard electrocardiograms (ECGs); and (3) manual measurements on standard ECGs, and compared on a QT versus time plot. An abnormal QT was determined based on the QT nomogram. Manual QT measurements showed a clear temporal association between ziprasidone overdose and a long QT, consistent with accurate QT measurements using continuous 12-lead Holter recordings with automatic QT measurements. However, standard automated measurements did not indicate an abnormal QT.
Conclusions:
Manual measurement of the QT interval appeared to be similar to the more accurate measurement of the QT by automated digital Holter recordings and better than standard automated measurements. Manual QT measurements would be more appropriate in clinical assessment of patients.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Antiarrhythmic Drugs: Class IV Agents as Calcium Channel Blockers
Verapamil, a calcium channel blocker, inhibits calcium movement across myocardial cell membranes and vascular smooth muscle. This results in the dilation of coronary and...

