Related Experiment Video
Updated: May 30, 2026

Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Reliability of the 8-repetition maximum test in men and women
J David Taylor1, James P Fletcher
1University of Central Arkansas, Department of Physical Therapy, Physical Therapy Center, Conway, AR 72035, USA. dtaylor@uca.edu
Objective:
The 8-repetition maximum test has been recommended as a method of prescribing an intensity for resistance training in healthy adults, athletes, and patients with health conditions. Yet, limited research related to the reliability of 8-repetition maximum testing has been conducted. The purpose of this study was to determine the reliability of the 8-repetition maximum test in men and women.
Design:
Test-retest reliability study.
Methods:
Twenty-eight people (14 males, 14 females, mean age=23.0 years [standard deviation=1.3]) with no exercise contraindications participated in this study. After familiarization, each participant underwent 8-repetition maximum testing using 4 different exercises. For all participants, the 8-repetition maximum test was performed during 2 sessions with 2-3 days between sessions. The intraclass correlation coefficient (ICC([1,2])), typical error as the coefficient of variation (TE(CV)), and the Bland-Altman plot were used to assess reliability. Unpaired t-test was used to determine the influence of gender on differences between initial test and retest values.
Results:
Excellent reliability of the 8-repetition maximum test was found for all exercises (ICC([1,2])>0.9). The range of TE(CV) values was 3.4-10.4%. The Bland-Altman plot illustrated that 27 out of 28 data points for total 8-repetition maximum scores were within the 95% limits of agreement. Unpaired t-test indicated no significant difference between men and women in variations between initial test and retest 8-repetition maximum scores.
Conclusion:
The findings of this study suggest that an 8-repetition maximum test protocol that includes familiarization is reliable in men and women.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
09:40Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
Published on: January 19, 2017