Assessment of cardiac output measurement in dogs by transpulmonary pulse contour analysis
Andre Shih1, Herbert W Maisenbacher, Carsten Bandt
1Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL 32610, USA. shih60@ufl.edu
Objective:
To determine if metatarsal artery pressure (COmet) is comparable to femoral artery pressure (COfem) as the input for transpulmonary pulse contour analysis (PiCCO) in anesthetized dogs, using the lithium dilution method (LiDCO) as a standard for cardiac output (CO) measurement.
Design:
Prospective randomized study.
Setting:
University research laboratory.
Animals:
Ten healthy purpose-bred mixed breed dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO.
Interventions:
The CO was measured using LiDCO and PiCCO techniques. Animals had their right femoral and left distal metatarsal artery catheterized for proximal (COfem) and distal (COmet) PiCCO analysis, respectively. Measurements were obtained from each animal during low, normal, and high CO states by changing amount of inhalant anesthetics and heart rate. Measurements were converted to CO indexed to body weigh (CI(BW) =CO/kg) for statistical analysis. Agreement was determined using Bland and Altman analysis and concordance correlation coefficients.
Measurements And Main Results:
Thirty paired measurements were taken. The LiDCO CI(BW) (± SD) was 68.7 ± 30.3, 176.0 ± 53.0, and 211.1 ± 76.5 mL/kg/min during low, normal, and high CO states, respectively. There was a significant effect of CI(BW) state on bias and relative bias with COmet (P<0.001 and P=0.003, respectively). Bias of the COmet method (± SD) was -116.6 (70.5), 20.1(76.4), and 91.3 (92.0) mL/kg/min at low, normal, and high CI(BW), respectively. Bias of the COfem (± SD) was -20.3 (19.0), 8.6 (70.9), and -2.9 (83.0) mL/kg/min at low, normal, and high CI(BW) , respectively. The mean relative bias for COfem was -6.7 ± 44% (limits of agreements: -81.2 to 67.9%).
Conclusion:
Compared with lithium dilution, the pulse contour analysis provides a good estimation of CO, but requires femoral artery catheterization in anesthetized dogs.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: