Objectives:
The aim was to prospectively characterise the effect of the level of breath-hold on heart rate in CT coronary angiography (CTCA) with prospective electrocardiogram (ECG) triggering and its impact on coronary artery attenuation.
Methods:
260 patients (86 women; mean age 59 ± 11 years) underwent 64-slice CTCA using prospective ECG triggering. Prior to CTCA, heart rates were recorded during 15 s of breath-hold at three different levels of inspiration (normal, intermediate and deep). The inspiration level with the lowest heart rate was chosen for actual CTCA scanning. Coronary artery attenuation was measured, and the presence of backflow of contrast material into the inferior vena cava (as an indicator of increased intrathoracic pressure) was recorded.
Results:
The mean heart rate at breath-hold was significantly different for the three inspiration levels (normal, 60 ± 8 bpm; intermediate, 59 ± 8 bpm; deep, 57 ± 7 bpm; p<0.001). The maximum heart rate reduction in each patient at breath-hold averaged 5.3 ± 5.1 bpm, and was observed at a normal inspiration depth in 23 (9%) patients, at an intermediate inspiration depth in 102 (39%) patients and at deep inspiration in 135 (52%) patients. Overall, there was no association between the level of breath-hold and coronary vessel attenuation (p-value was not significant). However, the backflow of contrast material into the inferior vena cava (n = 26) was found predominantly at deep inspiration levels (p<0.001), and, when it occurred, it was associated with reduced coronary attenuation compared with patients with no backflow (p<0.05).
Conclusion:
The breath-hold level to best reduce heart rate for CTCA should be individually assessed prior to scanning because a mean heart rate reduction of 5 bpm can be achieved.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes