Susceptometry-based MR oximetry has previously been shown suitable for quantifying hemoglobin oxygen saturation in large vessels for studying vascular reactivity and quantification of global cerebral metabolic rate of oxygen utilization. A key assumption underlying this method is that large vessels can be modeled as long paramagnetic cylinders. However, bifurcations, tapering, noncircular cross-section, and curvature of these vessels produce substantial deviations from cylindrical geometry, which may lead to errors in hemoglobin oxygen saturation quantification. Here, the accuracy of the "long cylinder" approximation is evaluated via numerical computation of the induced magnetic field from 3D segmented renditions of three veins of interest (superior sagittal sinus, femoral and jugular vein). At a typical venous oxygen saturation of 65%, the absolute error in hemoglobin oxygen saturation estimated via a closed-form cylinder approximation was 2.6% hemoglobin oxygen saturation averaged over three locations in the three veins studied and did not exceed 5% for vessel tilt angles <30° at any one location. In conclusion, the simulation results provide a significant level of confidence for the validity of the cylinder approximation underlying MR susceptometry-based oximetry of large vessels.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...