The influence of time and cement type on push-out bond strength of fiber posts to root dentin
Related Experiment Video
Updated: May 30, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
A A Leme1, M Coutinho, A F Insaurralde
1Cidade Universitária, Campo Grande, MS-Brazil.
Abstract:
The bond strength of fiber posts luted with resin cements was evaluated after two storage times in different regions of a post space. A total of 40 single-rooted human teeth were endodontically treated and prepared for cementation of fiber posts (White Post DC). In groups 1 and 3 (G1 and G3, respectively), posts were luted with RelyX ARC, whereas the posts in groups 2 and 4 (G2 and G4, respectively) were luted with RelyX Unicem. After one month of storage at 100% humidity, G1 and G2 were transversally sectioned in 1.7-mm slices of the cervical (C), middle (M), and apical (A) thirds of the post space and submitted to push-out testing at 1 mm/min. After nine months of storage, the roots of G3 and G4 underwent the same process. Mean values were analyzed using the Mann-Whitney and Kruskal-Wallis tests (α=0.05). The bond strengths in G2 (C=4.26±2.29; M=4.67±3.54; A=7.27±4.30) were statistically higher than in G1 (C=3.81±1.07; M=1.57±1.62; A=1.99±1.60) in the middle and apical thirds (p=0.001). Bond strengths in G4 (C=3.36±1.39; M=4.49±2.17; A=3.83±1.92) were higher than in G3 (C=2.13±0.47; M=0.94±1.05; A=0.95±1.02) in all evaluated regions (p=0.02, p<0.001, and p<0.001, respectively). When comparing the root regions for each group, G1 had higher values in the cervical third than the middle third (p=0.02). The self-adhesive resin cement showed better results than the conventional resin cement at both storage times. For both materials a similar performance among the three root regions was found. Storage time did not influence the shear bond strength.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Bonding and Strength of Aggregate
Setting Time of Cement
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Testing Water Quality
Factors Affecting Creep
Further, the water/cement ratio is critical, as a lower ratio increases concrete strength, thus reducing creep. The strength of the...