Application of flow-injection potentiometric system for determination of total concentration of aliphatic carboxylic acids
Related Experiment Video
Updated: May 29, 2026

Determination of Carbonyl Functional Groups in Bio-oils by Potentiometric Titration: The Faix Method
Published on: February 7, 2017
Monika Mroczkiewicz1, Łukasz Górski, Anna Zamojska-Jaroszewicz
1Warsaw University of Technology, Faculty of Chemistry, Institute of Biotechnology, Department of Microbioanalytics, Noakowskiego 3, 00-664 Warsaw, Poland.
Abstract:
In this work, flow-injection system with potentiometric detection was tested for determination of total carboxylic acid concentration. Detection part of the examined system consists of ion-selective electrodes (ISEs) with polymer membranes of different compositions. First electrode is based on Zr(IV)-tetraphenylporphyrin as ionophore selective towards carboxylic acid anions, the membrane of second one contains only liphophilic anion exchanger - tridodecylmethylammonium chloride. Final response of the system is a result of combination of EMF signals from both electrodes. Combination of two detectors enables significant decrease of differences between potentiometric signals induced by mixtures of studied anions of various concentrations as compared to results obtained only with metalloporphyrin-based ISE. The use of anion-exchanger based detector allows for elimination of the influence of aliphatic carboxylic acids lipophilicity. Proposed potentiometric flow-injection system was employed for determination of short-chain aliphatic carboxylic acids (so-called VFA - volatile fatty acids) in samples originating from an anaerobic digester. Results obtained for these relatively complicated samples are in good agreement with results obtained with the use of reference colorimetric method. Linear response towards carboxylic acids was observed in the concentration range of 10(-4) to 10(-2)mold m(-3), with the slopes in the range of -110 to -150 mV dec(-1) (for acetate(-) and butyrate(-), respectively). System enables for determination of about 6 samples per hour. Life time of ISEs average about 2 months.
More Related Videos
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
Related Concept Videos
Potentiometric Titration: Overview
Oxidations of Aldehydes and Ketones to Carboxylic Acids
Aldehydes readily undergo oxidation in strong oxidizing agents such as potassium permanganate and chromic acid. The oxidation can also be carried out using mild oxidizing agents such as silver oxide. In fact, aldehydes can be easily oxidized...
Controlled-Current Coulometry: Overview
Potentiometry: Overview
Acidity of Carboxylic Acids
Preparation of Carboxylic Acids: Overview