Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 29, 2026

Techniques of Endoscopic Ossiculoplasty
09:07

Techniques of Endoscopic Ossiculoplasty

Published on: January 26, 2024

An alternative multiple pontic design for a fixed implant-supported prosthesis.

Rafael Del Castillo1, Carlo Ercoli, Juan Carlos Delgado

  • 1Private practice, Alicante, Spain. casher@infomed.es

The Journal of Prosthetic Dentistry
|September 6, 2011
PubMed
Summary

A novel semiconvex pontic design improves fixed implant restorations for moderate ridge resorption. This approach addresses plaque, esthetics, and function, enhancing patient outcomes in multiple tooth replacement scenarios.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Biologic complications and implant survival rates associated with implant-supported fixed complete dental prostheses. A clinical study with a mean 29-month follow-up from implant placement.

The Journal of prosthetic dentistry·2026
Same author

Comparison of crestal bone levels, peri-implant indices, mucosal margin position, and pink esthetic score of posterior implant crowns fabricated with immediate vs delayed impressions: A 5-year retrospective cross- sectional study.

Journal of prosthodontics : official journal of the American College of Prosthodontists·2026
Same author

The influence of prosthetic designs on peri-implant bone loss: An AO/AAP systematic review and meta-analysis; inclusion bias and the importance of evidence-based conclusions in prosthodontic research.

Journal of prosthodontics : official journal of the American College of Prosthodontists·2025
Same author

Educating for tomorrow: integrating digital dentistry into today's curriculum.

Quintessence international (Berlin, Germany : 1985)·2025
Same author

Effect of the CBCT data segmentation threshold on registration accuracy with surface scanning.

The Journal of prosthetic dentistry·2025
Same author

The connective tissue cube for treatment of papillary deficiencies: A case report.

Clinical advances in periodontics·2025

Area of Science:

  • Dental Implantology
  • Prosthodontics
  • Biomaterials

Background:

  • Moderate residual ridge resorption presents challenges for fixed implant-supported restorations.
  • Designing the pontic-tissue interface is critical for function and esthetics.
  • Existing designs often lead to plaque accumulation, maintenance issues, and phonetic problems.

Purpose of the Study:

  • To introduce and describe a semiconvex multiple pontic design for fixed implant restorations.
  • To address challenges associated with pontic-tissue interface in cases of moderate ridge resorption.
  • To improve plaque control, maintenance, phonetics, and esthetics in implant restorations.

Main Methods:

  • A semiconvex multiple pontic design is proposed.
  • Mucosal contact is achieved with moderate pressure.

More Related Videos

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
08:15

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects

Published on: August 4, 2020

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 15, 2009

Related Experiment Videos

Last Updated: May 29, 2026

Techniques of Endoscopic Ossiculoplasty
09:07

Techniques of Endoscopic Ossiculoplasty

Published on: January 26, 2024

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
08:15

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects

Published on: August 4, 2020

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 15, 2009

  • Emphasis is placed on screw-retained, implant-supported restorations.
  • Main Results:

    • The semiconvex design aims to circumvent problems like plaque accumulation and compromised esthetics.
    • Moderate pressure on mucosal contact is utilized for improved outcomes.
    • Screw-retained restorations facilitate tissue contact and retrievability.

    Conclusions:

    • The semiconvex multiple pontic design offers a viable solution for fixed implant restorations in moderate ridge resorption.
    • This design can improve plaque control, maintenance, phonetics, and esthetics.
    • Screw-retained restorations are recommended for enhanced management and retrievability.