Related Experiment Video
Updated: May 29, 2026

Real-Time Analysis of Bioenergetics in Primary Human Retinal Pigment Epithelial Cells Using High-Resolution Respirometry
Published on: February 3, 2023
How to confirm C.E.R.A. doping in athletes' blood?
Nicolas Leuenberger1, Séverine Lamon, Neil Robinson
1Laboratoire Suisse d'Analyse du Dopage, Centre Universitaire Romand de Médecine Légale, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Epalinges, Switzerland. nicolas.leuenberger@chuv.ch
Abstract:
C.E.R.A. (Continuous Erythropoietin Receptor Activator) is a new third-generation erythropoiesis-stimulating agent that has recently been linked with abuse in endurance sports. The anti-doping community rapidly reacted by releasing a high-throughput screening ELISA allowing the detection of C.E.R.A. doping in athletes' blood. In order to return adverse analytical findings, anti-doping laboratories, however, need, as far as possible, to confirm the presence of the drug in athletes' samples through orthogonal methods. This article focuses on the comparison of 2 proposed confirmation assays based on gel electrophoresis that were coupled with a new sample immunopurification method. IEF, the classical method used to target erythropoietin (EPO) and its recombinant analogues in athletes' samples, and SARKOSYL-PAGE were applied to the plasma samples of subjects having received a single injection of C.E.R.A. It was demonstrated that SARKOSYL-PAGE was at least 6 times more sensitive than IEF, with comparable specificity. A longer detection window coupled with easier interpretation criteria led us to recommend the use of SARKOSYL-PAGE to confirm C.E.R.A. presence in athletes' blood.