Related Experiment Video
Updated: May 29, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Electromembrane extraction of stimulating drugs from undiluted whole blood
Ragnhild Elén Gjulem Jamt1, Astrid Gjelstad, Lars Erik Eng Eibak
1School of Pharmacy, Faculty of Mathematics and Natural Sciences, University of Oslo, PO Box 1068 Blindern, N-0316 Oslo, Norway.
Abstract:
For the first time, electromembrane extraction (EME) of six basic drugs of abuse from undiluted whole blood and post mortem blood in a totally stagnant system is reported. Cathinone, methamphetamine, 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-methamphet-amine (MDMA), ketamine and 2,5-dimethoxy-4-iodoamphetamine (DOI) were extracted from the whole blood sample, through a supported liquid membrane (SLM) consisting of 1-ethyl-2-nitrobenzene (ENB) immobilized in the pores of a hollow fiber, and into an aqueous acceptor solution inside the lumen of the hollow fiber. The SLM acts as a barrier with efficient exclusion of all macromolecules and acidic substances in the sample. Due to the application of the electrical field, only the cationic compounds of interest are extracted efficiently across the membrane, thus providing extremely clean extracts for analysis with liquid chromatography-mass spectrometry, LC-MS. Recoveries in the range 10-30% were obtained from 80 μl whole blood within 5 min extraction time and an applied voltage of 15V across the SLM. The optimized technique was tested on real forensic whole blood samples taken from three forensic autopsy cases and on five forensic whole blood samples from living persons. The results were in agreement with the analysis using standard sample preparation methods (liquid-liquid extraction) performed on the same samples by Norwegian Institute of Public Health (NIPH), Division of Forensic Toxicology and Drug Abuse Research. Evaluation data were acceptable, with limit of detections (LODs) in the range 40-2610 pg/mL, well below concentrations associated with drug abuse; linearites in the range between 10 and 250 ng/mL with r(2) values above 0.9939, and with repeatability (RSD) of 7-32%.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
06:59Rapid, Safe, and Simple Manual Bedside Nucleic Acid Extraction for the Detection of Virus in Whole Blood Samples
Published on: June 30, 2018
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...