Immobilized pH gradient-driven paper-based IEF: a new method for fractionating complex peptide mixtures before MS analysis
Related Experiment Video
Updated: May 29, 2026

Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method
Published on: June 14, 2020
Beerelli Seshi1, Kumaraguru Raja, Kh Chandramouli
1Department of Pathology and Laboratory Medicine, Los Angeles Biomedical Research Institute at Harbor-UCLA Medical Center, 1124 West Carson Street, Torrance, California 90502, USA. BSeshi@labiomed.org.
Introduction:
The vast difference in the abundance of different proteins in biological samples limits the determination of the complete proteome of a cell type, requiring fractionation of proteins and peptides before MS analysis.
Methods:
We present a method consisting of electrophoresis of complex mixtures of peptides using a strip of filter paper cut into 20 sections laid end to end over a 24-cm-long IPG strip, the pH gradient of which would drive the electrophoresis. Peptides absorbed onto individual paper pads after electrophoresis are subsequently recovered into a buffer solution, thus dividing a complex peptide mixture according to pI into 20 liquid fractions. This paper-based IEF method (PIEF) was compared side-by-side with a similar but liquid-based Offgel electrophoresis (OGE) by analyzing iTRAQ-labeled peptide mixtures of membrane proteins from four different cell types.
Results:
PIEF outperformed OGE in resolving acidic peptides, whereas OGE did a better job in recovering relatively basic peptides. OGE and PIEF were quite comparable in their coverage, identifying almost equal number of distinct proteins (PIEF =1174; OGE = 1080). Interestingly, however, only 675 were identified by both of them, each method identifying many unique proteins (PIEF = 499; OGE = 415). Thus, the two methods uncovered almost 40% more proteins compared to what is obtained by only one method.
Conclusion:
This initial investigation demonstrates the technical feasibility of PIEF for complementing OGE. PIEF uses standard IPG IEF equipment, requires no specialized apparatus (e.g., OGE fractionator) and may be integrated into peptide mapping strategies for clinical samples.
More Related Videos
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography

