Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pulse-pressure variation predicts fluid responsiveness during heart displacement for off-pump coronary artery bypass
Jong-Hwan Lee1, Yunseok Jeon, Jae-Hyon Bahk
1Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Objective:
The aim of this study was to evaluate the ability of pulse-pressure variation to predict fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery using receiver operating characteristic analysis.
Design:
A prospective study.
Setting:
A clinical study in a single cardiac anesthesia institution.
Participants:
Thirty-five patients undergoing elective off-pump coronary artery bypass surgery.
Measurements And Main Results:
Central venous pressure, pulmonary arterial occlusion pressure, pulse-pressure variation, and cardiac index were measured 5 minutes after revascularization of the left anterior descending coronary artery and before heart displacement. Immediately after heart displacement for revascularization of the left circumflex artery, and 10 minutes after fluid loading with hydroxyethyl starch 6% (10 mL/kg) during heart displacement, the measurements were repeated. Patients whose cardiac indices increased by ≥15% from fluid loading were defined as responders. After heart displacement, only pulse-pressure variation showed significant difference between the responders and nonresponders (13.48 ± 6.42 v 7.33 ± 3.81, respectively; p < 0.01). Moreover, receiver operating characteristic analysis showed that pulse-pressure variation successfully predicted fluid responsiveness (area under the curve = 0.839, p = 0.0001). Pulse-pressure variation >7.69% identified the responders, with a sensitivity of 86% and a specificity of 83%.
Conclusions:
Pulse-pressure variation successfully predicted fluid responsiveness and would be useful in guiding fluid management during heart displacement for off-pump coronary artery bypass surgery.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...