Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Vertical Curve: Problem Solving01:23

Vertical Curve: Problem Solving

Vertical curves provide the transition between two roadway grades, ensuring safety, comfort, and functionality. Calculating elevations at specific stations along the curve involves several systematic steps based on the curve's geometry and provided design parameters.The vertical curve is defined by its length, grades, Point of Vertical Intersection (P.V.I.) location, and P.V.I. elevation. The stations of the Point of Vertical Curvature (P.V.C.), where the curve begins, and the Point of Vertical...
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Method of Sections: Problem Solving I01:27

Method of Sections: Problem Solving I

Consider a symmetrical roof truss structure, composed of vertical, diagonal, and horizontal members. The length of each horizontal member is 4 m. The lengths of the vertical members FB and HD are 4 m, while the length of member GC is 6 m. The loads acting at joints F, G, and H are 2 kN, while those at joints A and E are 1 kN.
Method of Sections: Problem Solving II01:30

Method of Sections: Problem Solving II

Consider an arbitrary truss structure composed of diagonal, vertical, and horizontal members fixed to the wall. To calculate the force acting on members CB, GB, and GH, method of sections can be used. The loads and lengths of the horizontal and vertical members are known parameters, as shown in the figure.
Design Example: Traverse Angle Computations01:25

Design Example: Traverse Angle Computations

Traverse angle computations are a critical component of surveying, used to compute the internal angles within a closed traverse. A traverse consists of a series of connected lines forming a closed loop, often used for land boundary delineation or mapping. Calculating the internal angles ensures accuracy in the traverse geometry and is essential for checking survey data integrity.The process begins with known azimuths and bearings of the traverse sides. Internal angles at each vertex are...
Hydraulic Jump: Problem Solving01:16

Hydraulic Jump: Problem Solving

To analyze a hydraulic jump in a rectangular channel with a flow speed of 6 meters per second, follow these steps:Calculate Effective Upstream Velocity:When the downstream gate closes, a hydraulic jump forms, traveling upstream at 2 meters per second. This wave speed combines with the initial channel flow velocity, creating an effective upstream velocity.Identify Flow Velocities Before and After the Hydraulic Jump:Upstream of the hydraulic jump, the effective flow velocity includes both the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Early Feasibility Studies in Europe: A Multisite Qualitative Study of Operational Challenges and Site Selection Determinants at 6 University Hospitals.

Clinical therapeutics·2026
Same author

Prediction of peri-procedural cerebrovascular accidents in patients with severe peripheral artery disease undergoing transcatheter aortic valve replacement.

Vascular pharmacology·2026
Same author

Use of cangrelor in patients with reduced renal function: Post-hoc analysis from the ARCANGELO study.

International journal of cardiology·2026
Same author

First Large Comprehensive Core-Laboratory Evaluation of Implantation Depth and Clinical Outcomes in TAVR: Final Global Results from the Optimize PRO Prospective Study.

JACC. Cardiovascular interventions·2026
Same author

Computed Tomography Sizing Algorithm for Transcatheter Aortic Valve Implantation in Bicuspid Valve: Results From the CASPER Registry.

The Canadian journal of cardiology·2026
Same author

Physiology-guided percutaneous coronary intervention using drug-coated balloon versus drug-eluting stent: a propensity-matched analysis.

Journal of cardiovascular medicine (Hagerstown, Md.)·2026

Related Experiment Video

Updated: May 29, 2026

Biocytin Recovery and 3D Reconstructions of Filled Hippocampal CA2 Interneurons
11:21

Biocytin Recovery and 3D Reconstructions of Filled Hippocampal CA2 Interneurons

Published on: November 20, 2018

How to solve difficult side branch access?

Francesco Burzotta1, Maria De Vita, Gregory Sgueglia

  • 1Institute of Cardiology, Catholic University of Sacred Heart, Largo Gemelli 1, Rome, Italy. f.burzotta@rm.unicatt.it

Eurointervention : Journal of Europcr in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
|September 21, 2011
PubMed
Summary
This summary is machine-generated.

Successful percutaneous coronary interventions (PCI) in bifurcated lesions depend on safe guidewire placement in the main vessel (MV) and side branch (SB). This paper details essential and advanced wiring and rewiring techniques for optimal PCI outcomes.

More Related Videos

Automatic Identification of Dendritic Branches and their Orientation
06:08

Automatic Identification of Dendritic Branches and their Orientation

Published on: September 17, 2021

Related Experiment Videos

Last Updated: May 29, 2026

Biocytin Recovery and 3D Reconstructions of Filled Hippocampal CA2 Interneurons
11:21

Biocytin Recovery and 3D Reconstructions of Filled Hippocampal CA2 Interneurons

Published on: November 20, 2018

Automatic Identification of Dendritic Branches and their Orientation
06:08

Automatic Identification of Dendritic Branches and their Orientation

Published on: September 17, 2021

Area of Science:

  • Interventional Cardiology
  • Medical Devices
  • Vascular Surgery

Background:

  • Percutaneous coronary interventions (PCI) for bifurcated lesions require precise guidewire manipulation.
  • Successful outcomes in bifurcation PCI hinge on safe guidewire placement in both the main vessel (MV) and side branch (SB).
  • Guidewire techniques are critical, especially during complex procedures involving rewiring after MV stenting.

Purpose of the Study:

  • To describe classic and advanced guidewire techniques for bifurcation PCI.
  • To provide detailed insights into rewiring strategies for optimal provisional stenting.
  • To offer solutions for managing acute side branch (SB) flow impairment post-MV stenting.

Main Methods:

  • Description of antegrade and pullback wiring techniques for routine bifurcation interventions.
  • Explanation of advanced techniques including reverse wire, Venture-facilitate wiring, MV balloon predilation, and debulking.
  • Detailed discussion of rewiring techniques, focusing on tips and tricks for provisional stenting and bail-out situations.

Main Results:

  • The paper outlines a comprehensive approach to guidewire manipulation in bifurcation PCI.
  • It details techniques to facilitate successful wiring and rewiring, crucial for treating the SB.
  • Specific strategies are presented to manage complications like acute SB flow impairment.

Conclusions:

  • Mastery of guidewire techniques, including advanced methods and rewiring, is fundamental for successful bifurcation PCI.
  • The described techniques aim to improve procedural success and patient outcomes.
  • Effective management of SB wiring and rewiring is key to achieving optimal results with provisional stenting.