Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Non-monotonic material contrast in scanning ion and scanning electron images
1FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124, USA. Lucille@LAGiannuzzi.com
Abstract:
30keV Ga(+) focused ion beam induced secondary electron (iSE) imaging was used to determine the relative contrast between several materials. The iSE signal compared from C, Si, Al, Ti, Cr, Ni, Cu, Mo, Ag, and W metal layers does not decrease with an increase in target atomic number Z(2), and shows a non-monotonic relationship between contrast and Z(2). The non-monotonic relationship is attributed to periodic fluctuations of the stopping power and sputter yield inherent to the ion-solid interactions. In addition, material contrast from electron-induced secondary electron (eSE) and backscattered electron (BSE) images using scanning electron microscopy (SEM) also shows non-monotonic contrast as a function of Z(2), following the periodic behavior of the stopping power for electron-solid interactions. A comparison of the iSE and eSE results shows similar relative contrast between the metal layers, and not complementary contrast as conventionally understood. These similarities in the contrast behavior can be attributed to similarities in the periodic and non-monotonic function defined by incident particle-solid interaction theory.
More Related Videos
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
11:03Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy
Published on: July 14, 2022
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Overview of Electron Microscopy
Preparation of Samples for Electron Microscopy
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...