Strong coherence between heart rate variability and intracardiac repolarization lability during biventricular pacing is associated with reverse electrical remodeling of the native conduction and improved outcome
Related Experiment Video
Updated: May 29, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Larisa G Tereshchenko1, Charles A Henrikson, Ronald D Berger
1The Division of Cardiology, Department of Medicine, Johns Hopkins Hospital, Baltimore, MD, USA. lteresh1@jhmi.edu
Insights
Cardiac resynchronization therapy (CRT) can improve heart function. Stronger coherence between heart rate variability and repolarization during CRT is linked to reverse electrical remodeling, potentially reducing mortality risk.
Area of Science:
- Cardiology
- Electrophysiology
- Medical Devices
Background:
- Reverse electrical remodeling (RER) improves outcomes with cardiac resynchronization therapy (CRT) but its mechanisms are unclear.
- Understanding RER is crucial for optimizing CRT efficacy and patient survival.
- This study investigates repolarization lability during biventricular pacing to elucidate RER mechanisms.
Purpose of the Study:
- To explore repolarization lability during biventricular pacing in patients undergoing CRT.
- To identify predictors of reverse electrical remodeling (RER) in CRT recipients.
- To assess the association between repolarization dynamics and clinical outcomes.
Main Methods:
- Measured native QRS duration before and after CRT-D implantation in 69 heart failure patients.
- Defined RER as a QRS duration narrowing of ≥10 milliseconds.
- Analyzed beat-to-beat QT variability and coherence using surface ECG and intracardiac electrograms during biventricular pacing.
Main Results:
- RER was observed in 32% of patients.
- Patients with RER showed stronger coherence between heart rate variability and intracardiac repolarization lability (0.483 vs 0.237, P=.018).
- Low intracardiac coherence (≤0.116) significantly increased the risk of death or sustained ventricular tachycardia/fibrillation (HR 4.33, P=.006).
Conclusions:
- Strong coherence between heart rate variability and intracardiac repolarization lability during biventricular pacing is associated with RER in CRT.
- Low coherence predicts an increased risk of adverse events, including death and ventricular arrhythmias.
- These findings highlight repolarization dynamics as a key factor in CRT response and patient prognosis.
Background:
Reverse electrical remodeling (RER) of the native conduction with cardiac resynchronization therapy (CRT) is associated with decreased mortality and antiarrhythmic effect of CRT. Still, mechanisms of RER are largely unknown. In this study, we explored repolarization lability during biventricular pacing.
Methods And Results:
The width of native QRS was measured in lead II electrocardiogram before and at least 6 months after implantation of Cardiac Resynchronization Therapy Defibrillator (CRT-D) devices (Medtronic, Inc [Minneapolis, MN, USA] and Boston Scientific Corporate [Natick, MA, USA]) in 69 patients (mean age, 66.3 ± 13.9 years; 39 men [83%]) with either bundle-branch block (44 patients [64%]) or nonspecific intraventricular conduction delay (25 patients [36%]) and New York Heart Association class III and IV heart failure. Narrowing of the native QRS duration for at least 10 milliseconds was considered a marker of RER. Beat-to-beat QT variability and coherence was measured on surface electrocardiogram and intracardiac near-field electrogram during biventricular pacing. Reverse electrical remodeling was observed in 22 patients (32%) in whom coherence between heart rate variability and intracardiac repolarization lability was stronger (0.483 ± 0.243 vs 0.237 ± 0.146, P = .018) and normalized intracardiac QT variance was smaller (0.28 ± 0.0031 vs 0.46 ± 0.0048, P = .049), as compared with that in patients without RER. During a further 24 ± 13 months of follow-up, 21 patients (33%) died or experienced sustained ventricular tachycardia (VT)/ventricular fibrillation. Low intracardiac coherence (≤0.116) was associated with increased risk of death or sustained VT/VT (hazard ratio, 4.33; 95% confidence interval, 1.51-12.40; P = .006).
Conclusion:
Strong coherence between heart rate variability and intracardiac repolarization lability during biventricular pacing is associated with RER of the native conduction with CRT. Low coherence is associated with increased risk of VT/ventricular fibrillation or death.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
