Compression-compression fatigue of selective electron beam melted cellular titanium (Ti-6Al-4V)
Nikolas W Hrabe1, Peter Heinl, Brian Flinn
1Materials Science and Engineering Department, University of Washington, 302 Roberts Hall, Seattle, Washington 98195-2120, USA. nhrabe@gmail.com
Abstract:
Regular 3D periodic porous Ti-6Al-4V structures intended to reduce the effects of stress shielding in load-bearing bone replacement implants (e.g., hip stems) were fabricated over a range of relative densities (0.17-0.40) and pore sizes (approximately 500-1500 μm) using selective electron beam melting (EBM). Compression-compression fatigue testing (15 Hz, R = 0.1) resulted in normalized fatigue strengths at 10(6) cycles ranging from 0.15 to 0.25, which is lower than the expected value of 0.4 for solid material of the same acicular α microstructure. The three possible reasons for this reduced fatigue lifetime are stress concentrations from closed porosity observed within struts, stress concentrations from observed strut surface features (sintered particles and texture lines), and microstructure (either acicular α or martensite) with less than optimal high-cycle fatigue resistance.