Related Experiment Video
Updated: May 28, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Photoelastic stress analysis of external versus internal implant-abutment connections
Pattapon Asvanund1, Steven M Morgano
1Mahidol University, Bangkok, Thailand.
Statement Of Problem:
Common complications of implant restorations are abutment screw loosening and screw fracture. The geometry of the implant-abutment connection may affect stresses generated from loading, and these stresses may have a role in screw loosening or fracture.
Purpose:
This study compared the load transfer characteristics of a complete-arch restoration supported by 4 implants with external and internal implant-abutment connections. Loads were applied to the prostheses in 3 positions.
Material And Methods:
Two-dimensional photoelastic models were used to simulate bone. Two types of implants (ReplaceSelect Internal-Interface Tapered Implants and ReplaceSelect External-Interface Tapered Implants) were placed in the photoelastic models. Complete-arch metal frameworks were fabricated on the abutments. Artificial teeth were arranged on the framework, and the prosthesis was screwed onto the abutments. The specimens were analyzed at 2 levels (implant-abutment level and apical to the implant level) with 3 loading conditions (4-point load; 2-point anterior load; and 2-point lateral load). The numbers of fringe orders were recorded and compared.
Results:
With the 4-point load, no stress differences occurred between the external-implant abutment connection and internal-implant abutment connection at the connection level and at the apical level. With the 2-point anterior load, the internal-implant abutment connection resulted in lower stresses at the connection level both in the loaded and non-loaded areas. With the 2-point lateral load, the internal-implant abutment connection resulted in lower stresses at the connection level at the non-loaded area.
Conclusions:
When loaded off-center, the internal-implant abutment connection produced less stress when compared with the external-implant abutment connection.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Stress Concentrations
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal loadings...
Applications of Stress
The...