Related Experiment Video
Updated: May 28, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Clinical predictors and institutional variation in home oxygen use in preterm infants
Joanne Lagatta1, Reese Clark, Alan Spitzer
1Medical College of Wisconsin, Milwaukee, WI 53204, USA. jlagatta@mcw.edu
Objective:
To assess home oxygen use in preterm infants, identify risk factors predicting home oxygen use, and quantify the extent of institutional variation in home oxygen use across neonatal intensive care units.
Study Design:
We conducted a retrospective cohort analysis of surviving infants of 23- to 31-week gestational age discharged home in 2009, with de-identified electronic medical record information from the Pediatrix Clinical Data Warehouse. Mixed-effects logistic regression quantified clinical risk factors and institutional variation affecting home oxygen use.
Results:
A total of 8167 infants were identified. Home oxygen use varied by gestational age, from 59% of infants 23 to 24 weeks gestational age to 7% of infants 29 to 31 weeks gestational age. Other risk factors included small for gestational age, congenital anomalies, mechanical ventilation in the first 72 hours, fraction of inhaled oxygen >0.4 in the first 72 hours, and patent ductus arteriosus. After adjusting for clinical risk factors, there was still a 4- to 5-fold difference in institutions' odds of home oxygen use.
Conclusions:
Home oxygen use was common in infants of earlier gestational ages and infants with more severe respiratory illness. Institutional variation accounted for 4- to 5-fold variation in home oxygen use. Families should be counseled about the likelihood of home oxygen use, and prospective research must identify optimal treatment strategies for high-risk infants.
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: