Related Experiment Video
Updated: May 28, 2026

A Rat Model of Mild Intrauterine Hypoperfusion with Microcoil Stenosis
Published on: January 7, 2018
Perioperative safety of Hydrosoft coils
Ben Waldau1, Aquilla S Turk, Parham Yashar
1Department of Neurosurgery, University of Florida, Gainesville, FL 32610, USA.
Objective:
Hydrosoft coils were developed to serve as finishing coils to prevent aneurysmal recurrence at the neck. Initial animal studies were encouraging since some studies showed endothelial healing across the neck without recurrence over time. However, theoretical concerns exist regarding the potential threat to parent vessels as the Hydrosoft coils at the neck expand, as well as whether such coils can be adequately supple to safely serve as a true finishing coil. A retrospective review of the initial clinical experience utilizing Hydrosoft coils from three high-volume centers was performed.
Methods:
Each center was asked to report angiographic (aneurysmal location, aneurysmal maximal size, neck size, incidence of intraprocedural parent vessel thrombosis, coil herniation, aneurysmal rupture as well as Raymond scale and percent occlusion after coiling) and clinical (rupture status, Hunt and Hess grade, incidence of stroke, hemorrhage, vasospasm and hydrocephalus) data on consecutive patients who underwent placement of Hydrosoft coils.
Results:
A total of 141 patients were enrolled. Embolization achieved a Raymond scale score of I (complete obliteration) in 79 aneurysms (56%), II (residual neck) in 40 aneurysms (28%) and III (residual dome) in 21 aneurysms (15%); in one case the Hydrosoft coil could not be placed. Procedural morbidity and mortality were 2.1% and 1.4%, respectively. No complications were definitively attributed to the use of Hydrosoft coils. There were three cases (2.1%) of parent vessel thrombosis, two of which resolved after intraprocedural administration of thrombolytic agents and did not lead to neurological sequelae. The incidences of intraprocedural or periprocedural aneurysmal rupture (2.1%), cerebral hemorrhage (3.5%), stroke (4.9%), vasospasm (26.2%) or hydrocephalus (31.1%) were comparable to contemporary literature.
Conclusion:
The use of Hydrosoft coils appears to be safe and does not lead to higher complication rates than are currently accepted in the literature. Further prospective studies are required to determine whether the use of Hydrosoft coils results in a lower incidence of aneurysmal recurrence.
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Cardiac Catheterization IV: Nursing Management
Aneurysm IV: Nursing Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Cardiomyopathy VII: Pre and Post Operative Nursing Management