In-patient to isocenter KERMA ratios in CT
Walter Huda1, Kent M Ogden, Robert L Lavallee
1Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC 29425-3230, USA.
Purpose:
To estimate in-patient KERMA for specific organs in computed tomography (CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom.
Method:
A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma K(CT) at the CT scanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (R(K)) as K∕ K(CT), which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). R(K) values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CT dosimetry. CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV.
Results:
At 120 kV, median R(K) values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile R(K) values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile R(K) values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average R(K) for the 25 Rando organs at 120 kV was 0.61 ± 0.08. Average R(K) values in the head, chest, and abdomen showed little variation. Relative to R(K) values in the head, chest, and abdomen obtained at 120 kV, R(K) values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average R(K) values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in R(K) value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average R(K) value by 9%.
Conclusions:
In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organ doses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissue dose would require the use of energy-appropriate conversion factors.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT