Related Experiment Video
Updated: May 28, 2026

Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation
Published on: June 26, 2018
Spinal cord stimulation with percutaneous leads after loss of coverage with implanted surgical lead
Alexander E Yakovlev1, Beth E Resch
1Comprehensive Pain Management of the Fox Valley, Appleton, WI, USA.
Objective:
This case report presents an application of percutaneous spinal cord stimulation to a patient with complex regional pain syndrome type 1 involving the bilateral lower extremities with loss of coverage with surgical lead.
Measurements:
The patient underwent an uneventful spinal cord stimulator trial with percutaneous placement of two temporal eight-electrode epidural leads (Medtronic Inc, Minneapolis, MN, USA) to level T11.
Results:
Upon experiencing excellent pain relief over the next three days, the patient was implanted with permanent leads and rechargeable generator four weeks later and reported sustained pain relief.
Conclusion:
Percutaneous spinal cord stimulation offers an alternative treatment option for the patient with loss of coverage with surgical lead.