Prevention of pressure ulcer: interaction of body characteristics and different mattresses
Theodoros Moysidis1, Wolfgang Niebel, Katharina Bartsch
1Department of Angiology, HELIOS Klinik Krefeld, Lutherplatz 40, Krefeld, Germany.
Abstract:
We analysed the effect of different body features on contact area, interface pressure and pressure distribution of three different mattresses. Thirty-eight volunteers (age ranged from 17 to 73 years, 23 females) were asked to lie on three different mattresses in a random order: I, standard hospital foam mattresses; II, higher specification foam mattresses (Viscorelax Sure® ); III, constant low pressure devices (CareMedx® , AirSystems). Measurements were performed in supine position and in a 90° left- and right-sided position, respectively, using a full-body mat (pressure mapping device Xsensor X2-Modell). Outcome variables were contact area (CA) in cm(2) , mean interface pressure (IP) in mmHg and pressure distribution (PD) estimated as rate of low pressures between 5 and 33 mmHg on each mattress in percent. Mean CA was lowest in the standard hospital foam mattresses and increased in the higher specification foam mattresses and was highest in the constant low pressure device (supine position: 491 ± 86 cm(2) , 615 ± 95 cm(2) , 685 ± 116 cm(2) ). Mean IP was highest in the standard hospital foam mattresses and lower but similar in the higher specification foam mattresses and the constant low pressure devices (supine position: 22·3 ± 1·5 mmHg, 17·6 ± 1·7 mmHg, 17·6 ± 2·2 mmHg). Models were estimated for CA, IP and PD including the independent variables height, weight and waist-to-hip-ratio (WHR). They show that body morphology seems to play a minor role for CA, IP and PD, but very thin and tall patients and very small and obese people might benefit from different mattresses. Our data show that CA increases with increasing specification of mattresses. Higher specification foam mattresses and constant low pressure devices show similar IP, but constant low pressure devices show a wider pressure distribution. Body morphology should be considered to optimise prevention for single patients.
Related Concept Videos
Peripheral Artery Disease IV: Nursing Management
The Scientific Method in Nursing Process
When using research findings to change practice, one must understand the process used to guide a study. The scientific method is a systematic, step-by-step process that supports the data's validity, reliability, and generalizability. As a result, findings can be safely...
Pre-Procedural Guidelines for Assessing Blood Pressure
Peptic Ulcer Disease I: Introduction
An acute ulcer, marked by superficial erosion and minimal inflammation, swiftly resolves upon identifying and addressing the underlying cause. In contrast, a chronic ulcer persists, potentially eroding through the muscular wall and forming fibrous tissue.
Peptic ulcers can also be...
Atherosclerosis IV: Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...