Related Experiment Video
Updated: May 28, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
A 1-year prospective study on Co-Axis implants immediately loaded with a full ceramic crown
Stefan Vandeweghe1, Jan Cosyn, Eric Thevissen
1Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium.
The Co-Axis implant demonstrated 100% survival and stable bone levels after 6 months, indicating a successful immediate loading protocol for dental implants. Patients reported improved well-being and good aesthetic outcomes with full ceramic crowns.
Area of Science:
- Dental Implantology
- Prosthodontics
- Periodontology
Background:
- The Co-Axis implant features a 12-degree angled neck to address angulation challenges in dental implant placement.
- Immediate loading protocols are increasingly utilized to shorten treatment times in restorative dentistry.
Purpose of the Study:
- To evaluate the clinical outcomes of the Co-Axis implant system after 1 year of function.
- To assess bone loss, peri-implant soft tissue health, and aesthetic results following immediate loading with a full ceramic crown.
Main Methods:
- Fifteen Co-Axis implants were placed in the premaxilla of 14 patients and immediately loaded with screw-retained full ceramic crowns.
- Bone loss was measured via periapical radiographs; soft tissue changes, plaque, and bleeding indices were assessed.
- Patient satisfaction was evaluated using the Oral Health Impact Profile-14 (OHIP-14) questionnaire.
Main Results:
- All implants achieved 100% survival at 1 year, with mean bone loss of 1.20 mm, stabilizing after 6 months.
- Low plaque levels were maintained; bleeding on probing decreased initially and remained stable.
- Four instances of screw loosening and one porcelain chip occurred; midfacial recession was 0.37 mm, with minor papilla changes.
Conclusions:
- The Co-Axis implant system demonstrated favorable clinical outcomes with immediate loading, evidenced by 100% implant survival and stable bone levels.
- Full ceramic crowns provided good aesthetic results, though soft tissue stability, particularly midfacial recession, required 1 year for assessment.
- Despite minor complications like screw loosening, patient-reported outcomes indicated increased well-being.
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Eccentric Axial Loading in a Plane of Symmetry